IEC/EN62471 Mobile Iris Recognition BMP Format With Live Detection

Product Details

Place of Origin: China

Brand Name: HOMSH

Certification: ISO9001

Model Number: C41

Payment & Shipping Terms

Delivery Time: 5-8 work day

Payment Terms: T/T

Get Best Price
Highlight:

Mobile Iris Recognition Live Detection

,

EN62471 Mobile Iris Recognition

Product Model:
C41
Product Size:
95*45*30mm
Iris Image Format:
BMP Format
Iris Image Size:
The Monocular Iris Image Is 640 Pixels Wide And 480 Pixels High
Infrared Assisted Lighting:
2*850nmLED,<100W/m3
Average Acquisition Time:
≤0.7s
Product Model:
C41
Product Size:
95*45*30mm
Iris Image Format:
BMP Format
Iris Image Size:
The Monocular Iris Image Is 640 Pixels Wide And 480 Pixels High
Infrared Assisted Lighting:
2*850nmLED,<100W/m3
Average Acquisition Time:
≤0.7s
IEC/EN62471 Mobile Iris Recognition BMP Format With Live Detection

 

Mobile Iris Capture Recognizer Easy To Use: Mobile Collection Verification Can Be Completed

Description

 

C41 is an external iris suitable for mobile terminal use
Identify the device. C41 has a unique magnetic adaptive back clip,
Applicable to various types of police mobile phones, mobile collection can be completed
Verification, can be equipped with acquisition and recognition APP, to achieve the iris body
A verification, with voice, light prompt function, one
The design is not easy to drop the line, and the reflection of the whole lens assists the positioning.
The C41 is suitable for mobile law enforcement by public security personnel.

  The mobile identity verification APP installed on the mobile terminal can collect iris information of suspicious personnel and send it to the iris identity verification system through the mobile terminal for iris identity verification. It is suitable for public security personnel Mobile Law Enforcement Use.

 

Features

 

◎ The equipment meets the requirements of "Technical Requirements for Iris collection Equipment for Criminal Investigation Business" (for the construction of iris library of the sub-system of tens of millions of sentences);
◎ Live body detection can prevent prosthetic attacks in the form of iris photos and iris videos;
◎ Products can be matched with iris collection and recognition APP to complete the iris identity verification of personnel;
◎ Exquisite fuselage, voice, light prompt assistance, easy to use;
◎ Equipped with a retractable back clip base, easy to fix on different models of mobile phones;
◎ The device is fixed with the base through magnetic suction, easy to disassemble;
◎ USB interface adopts integrated design, to prevent the use of the process do not touch resulting in disconnection;
◎ Full reflection lens, convenient identification and positioning.

 

 

Specifications

 

Product model

C41

Product size

95*45*30mm

In vivo detection

With live detection, it can prevent prosthetic attacks in the form of iris photos and iris videos

Iris image format

BMP format

Iris image size

The monocular iris image is 640 pixels wide and 480 pixels high

Iris image quality

Meet the "Technical Requirements for Iris acquisition Equipment for Criminal Detection Sound Business" (for Ziwan

The requirements of iris library construction of the special subsystem of punishment are detailed as follows

1. Equipment resolution: Within the range of effective acquisition distance, the equipment resolution is not less than 8

lp/mm :

2. Iris image sampling resolution: not less than 21 pixel/mm;

3, gray level of iris image: iris image is gray image, each pixel point depth

Not less than 8 bits, that is, the gray quantization level of each pixel in the image is not less than 256 levels:

Iris image quality

4, iris image gray level utilization: not less than 6 bits:

5, iris image iris radius: not less than 100 image table:

6, iris and sclera contrast: not less than 10:

7. Iris and pupil contrast: not less than 30

8, the proportion of iris effective area: greater than 60%

9. Boundary margin: the fitting circle of the outer boundary of the iris to the upper and lower boundary of the iris image

The distance between the left boundary and the right boundary is not less than 0.5ri, 0.5ri, 1.0 ri and 1.0 ri, respectively, where ri

Is the radius of the iris.

Infrared assisted lighting

2*850nm LED,<100W/m3

Infrared safety standard

Compliant with American standard ANSI RP-27.1-96 compliant with EU standard IEC/EN62471

Working distance

14~16cm

Average acquisition time

≤0.7s

Working mode and connection

Connect the mobile phone through USB2.0 Type-C, APP control, automatic binocular acquisition

Operating voltage

5V USB power supply

Product power consumption

<3.5W

Installation mode

The base is arranged on the back of the mobile terminal through a retractable back clip, and passes between the device and the base

Magnetic fixation

Operating temperature

-10°C~55°C

Working ambient humidity 

0 to 93%RH, non-condensing

 

Application

 

C41 is used by public security personnel for mobile law enforcement.

 